LFV300 Level switch vibration.

LFV300 Vibrating level switch. For clean or dirty liquids

LFV300 Vibrating level switch. For clean or dirty liquids
Measuring principle vibrating
Measuring range up to 6000 mm
Output signal PNP/NPN - Dual relay (DPDT) - NAMUR signal
Attacks on the request process
Process temperature -50+250°C 
Pressure up to 64 bar
Hygienic versions according to EHEDG and FDA, suitable for CIP and SIP systems
On request ATEX version
Price from € 400,00
Variable depending on the configuration

The level sensor is a switch LFV300 vibrating level limit switch that detects the preset in the system filling liquid having pinpoint accuracy (even in harsh operating conditions).

The measurement principle of the oscillating fork reacts to variations in density between the surrounding air and the liquid running independently of the tank material, the structure of the container or of the liquid concerned.

The robust sensor requires no calibration with the medium and operates without wear or maintenance.
The area of use of the sensor is limitless. It can be used as limit switches in tanks, storage containers and interim or to protect the pumps from running dry (thanks to the principle of universal measuring LFV300 and to its flexible design).
There is a version for vertical mounting (up to 6 meters).
A wide range of flanges, wires and hygienic connections allows customers specific solutions.


This vibrating level switch is suitable for hygienic applications and can be cleaned with CIP and SIP processes.
Versions are also available for use in potentially explosive atmospheres in order to avoid overflow (in accordance with WHG) and marine certification.


Benefits

  • Do not require calibration
  • Good repeatability 

 

 

Technical Characteristics

Measuring principle:
    • Vibration
    Measuring range / adjustment:
      • from 40 mm to 6 m
      Outputs available:
        • DPDT contact
        • NAMUR
        • NPN/PNP
        Operating voltage [V]:
          • 20÷253 Vac | 20÷72 Vdc | 20÷253 Vdc
          Operating temperature:
            • -50÷+150 [°C]
            Ambient temperature:
              • -40÷+70 [°C]
              Pressure max:
                • -1+64 [Barg]
                Process connection:
                  • Thread GAS
                  • Thread NPT M
                  • Flanged
                  • Tri-clamp
                  • [up to the model]
                  Materials in contact with the media:
                    • Stainless steel AISI 316
                    Degree of protection:
                      • IP66
                      • IP67
                      Approvals:
                        • EHEDG approval
                        • RoHS certificate
                        • Gost R Approval
                        • ATEX Declaration
                        • ACMA Declaration of conformity
                        • EC Declaration of Conformity