G2X Total and instantaneous flow viewer

G2X90TDH77
The G2X is a digital flow viewer (total, instantaneous) with two alarm thresholds (active on the flow rate) with relay output.
The two frontal LEDs repeat the state of the relay outputs.
For each of the thresholds can be set: the threshold value, the alarm type desired (minimum, maximum, window, hysteresis), the differential.
The selection of reading, instant or total, is done by the UP.
At power ON the readout is designed for reading the instantaneous flow rate; pressing the UP switch to display the total capacity. Pressing returns to the instantaneous flow.
G2X90TDH77
Price per Unit
Qty | Unit price (Vat excluded) |
Unit price (Vat included) |
---|---|---|
1 | €185.00 | €225.70 |
In this section you will find all the variants available for this model. Improve your configuration with the drop-down menus below, select the desired quantity and click ADD TO CART
The price displayed refers to a specific configuration and varies based on the options selected.
Product features | |
---|---|
Programming method | From keyboard |
Documentation included | English instructions manual, Italian instructions manual |
Explosion protection | Safe zone |
Relative humidity of the process environment | 95 %rh |
Version | With 4...20mA output and Modbus RTU |
Mounting | Panel |
Ambient temperature | -10...+50 °C |
Main features | Viewing of measures without units, Total flow calculation, Istant flow calculation, Optional signal output, Scale zero adjustable, Full scale adjustable |
More features | |
Inputs | Pulses / digital inputs | Details of the signal inputs and outputs |
All signal outputs available | 4...20 mA, Modbus RTU, SPST Switches |
Signal Output Type | Uscite multiple |
Details of the signal outputs | Optional 4...20mA, Modbus RTU or two R1 relays; R2 with SPST contact 5A - 250V |
Output details | 1 x Analog 4…20 mA + 1 x Modbus RS485 | Registry features |
Display | Yes |
Display technology | 7 segments |
Touchscreen | No |
Display details | 6-digit display; maximum scale displayed 0…999999 | Electrical data |
Voltage type | 24 Vdc + 230 Vac |
Recovery battery | Not available |
Type of electrical connection | Double removable terminal block with screw terminals |
Reverse polarity protection | No |
Degree of protection | IP54 |
Status LED | SET reaching LEDs |
Absorbed power | 3,3 W |
Operating voltage | Double power supply 24 Vac/dc and 230 Vac |
Relay number | None |
Keypad details | Keyboard composed of 4 membrane keys:
|
Settings memory | EEPROM | Mechanical data |
Height | 48 mm |
Width | 96 mm |
Depth | 100 mm |
Case material | PPE - PPOm (NORYL®) - Polyphenylene oxide |
Hole/template dimensions | 92x45mm; depth: 100mm | Performance data |
Initialization time | 4 s | Approvals |
Naval approvals | None |
Food / pharmaceutical approvals | None |
Atex approvals | None |
Standards and Certifications | RoHS, Directive 2014/35/EU “Low voltage Directive”, Directive 2014/30/EU “Electromagnetic compatibility Directive” |
EMC applied harmonized standards | EN 61326 (For industrial applications) |
CE omologation | Yes |
Low voltage applied harmonized standards | EN 61010-1: 2010 |
Rohs applied harmonized standards | EN IEC 63000:2018 | Other informations |
Other technical data | DIGITAL INPUTS Optoisolated digital inputs configurable NPN or PNP Double counting input: IN1 from NPN or PNP sensor IN2 from clean mechanical contact RST1 = waiting input RST2 = enable / reset peak hold Maximum counting frequency:
OUTPUT RELAY Two R1 relays; R2 with SPST contact 5A - 250V |
Logistics |
Type of packaging | Carton BOX |
Contains batteries | Yes |
ETCN | N/D |
country of origin | Italy |
Customs Code | 85437090 |
Gross weight | 0,85 kg |
Net weight | 0,35 kg |
Packaging volume | 0,007 m³ |
Packing length | 26 cm |
Packaging width | 21 cm |
Packaging depth | 13 cm |
Wiring diagrams

Rear view and terminal block connections of the Riels G2X display.

Rear view and terminal block connections of the Riels G2X display.
Assembly diagrams


This proven flow sensor made of solid, lead-free brass ensures reliable service for many years, even under the extreme conditions encountered in professional machines.
- Measuring range 0,038...11,55 l/min
- Process temperature -10...+100°C
- Signal output NPN
- Process pressure Up to 20 bar

The FM flow sensor is ideal for accurately measuring flow in continuous applications, such as bottling plants, welding robots, and laser cooling systems. With its robust design and multijet measurement technology, it provides reliable performance and high accuracy.
- Measuring range 0,24...17 l/min
- Process temperature -10...+65°C
- Signal output NPN
- Process pressure Up to 20 bar

The FHKSC sensor is the perfect choice for applications that demand an excellent quality-to-price ratio, such as in-home coffee machines. Its compact size and extremely lightweight design make it highly adaptable to a wide range of installation environments.
- Measuring range Up to 0,91 l/min
- Process temperature -10...+65°C
- Signal output NPN
- Process pressure -1...0,3 bar

- Measuring range Up to 3,23 l/min
- Process temperature -10...+65°C
- Signal output NPN
- Process pressure -1...0,3 bar

The RIF400 is a volumetric flow meter ideal for measuring low flow rates of viscous liquids such as oils, hydraulic fluids, lubricants, fuels, diesel, adhesives, and resins. The output signal is square wave pulses with Hall effect.
- Measuring range up to 100 l/min
- Process temperature -40...+100°C
- Signal output pulsed
- Process pressure up to 32 bar

Product 938-3570/01 is a turbine sensor for general applications. It is used for measuring, regulating, or dosing and ensures accurate measurement of liquid quantities dispensed.
- Measuring range 1,4...18 l/min
- Process temperature -10...+65°C
- Signal output NPN
- Process pressure up to 20 bar

The FHKU 938-6500/01 flow meter offers exceptional versatility. Used for high flow rates up to 30 l/min. Compatible with all low and medium viscosity liquids.
- Measuring range 3...30 l/min
- Process temperature -10...+65°C
- Signal output NPN
- Process pressure up to 20 bar

The battery-powered FHKU LCD 938-A9xx/LE5xxx turbine flow meter can be used for a variety of purposes. Suitable for food liquids such as water, coffee and beer. Excellent for monitoring ion exchange filter cartridges and water treatment.
- Measuring range up to 10,82 l/min
- Process temperature 0...+60°C
- Signal output no output
- Process pressure up to 10 bar

- Measuring range up to 15,26 l/min
- Process temperature 0...+60°C
- Signal output no output
- Process pressure up to 10 bar

The turbine has a good repeatability of ±0.25% and an accuracy of ±2% which can be improved by performing a calibration in the field by modifying the calibration factor.
- Measuring range up to 10,79 l/min
- Process temperature -10...+100°C
- Signal output PNP or NPN
- Process pressure up to 20 bar

The turbine has a good repeatability of ± 0.25% and an accuracy of ±2% which can be improved by performing a calibration in the field by modifying the calibration factor.
- Measuring range up to 9,26 l/min
- Process temperature -10...+65°C
- Signal output PNP or NPN
- Process pressure up to 20 bar

.The turbine has a good repeatability of ± 0.25% and an accuracy of ± 2% which can be improved by performing a calibration in the field by modifying the calibration factor.
- Measuring range up to 30 l/min
- Process temperature -10...+100°C
- Signal output PNP or NPN
- Process pressure up to 20 bar

The turbine has a good repeatability of ±0.25% and an accuracy of ±2% which can be improved by performing a calibration in the field by modifying the calibration factor.
- Measuring range up to 9,26 l/min
- Process temperature -20...+65°C
- Signal output PNP or NPN
- Process pressure up to 10 bar

- Measuring range up to 9,26 l/min
- Process temperature 0...+60°C
- Signal output no output
- Process pressure up to 10 bar

- Measuring range up to 8,3 l/min
- Process temperature -10…+65°C
- Signal output PNP or NPN
- Process pressure up to 20 bar

- Measuring range up to 0,96 l/min
- Process temperature -10...+100°C
- Signal output PNP or NPN
- Process pressure up to 20 bar

The FHKU High flow turbine 938-2xx/xKxxx series is suitable for high liquid velocity hydraulic conditions. It generates a high number of pulses per liter making it suitable for precision dosing.
- Measuring range up to 7,42 l/min
- Process temperature -10...+100°C
- Signal output NPN
- Process pressure up to 20 bar

- Measuring range up to 11,5 l/min
- Process temperature -10...+100°C
- Signal output NPN
- Process pressure up to 20 bar

- Measuring range up to 30 l/min
- Process temperature -10...+65°C
- Signal output NPN
- Process pressure up to 20 bar

- Measuring range up to 7,42 l/min
- Process temperature -10...+100°C
- Signal output NPN
- Process pressure up to 20 bar