Programming method |
Keyboard + Software |
Documentation included |
English instructions manual |
Explosion protection |
Safe zone |
Relative humidity of the process environment |
95 %rh |
Mounting |
Panel |
Ambient temperature |
0...+50 °C |
Main features |
Datalogger, Data recorder, Viewing of measures with units, Total flow calculation, Istant flow calculation, Math channel, Optional signal output, WEB server, Modbus TCP server, .txt data saving, USB for data download, USB settings download, E-mail allarms |
More features |
• For each input there are available two totalizers L1 and L2 • Totalizers can be reset manually or they can work automatically: daily ,weekly or monthly • Totalizers T1 and T2 counting the operation time of totalizers • Frequency of archiving, for counters, from 1 min to 24h • 4 solid state relays 0,1 A / 60 V • 2 alarm and control thresholds for each channel • Recording data to internal 2GB memory, local access to recorded data through USB port on the front panel • Data recording rate between 2 s and 24 h; two recording frequencies toggled upon exceeding the set alarm thresholds • Measurement of flow and other quantities, e.g. temperature, humidity, pressure |
All signal outputs available |
4...20 mA, Modbus RTU, Modbus TCP |
Communication interface |
RS485 |
Analog output type |
4...20 mA |
Number of analog outputs |
1 |
Signal inputs details |
2 ANALOG INPUTS Independent setup for input sensors • Transducers with 4-20mA (with optional power supply from device) or 0-20mA current loop output • RTD sensors (Pt100, Pt200, Pt500, Pt1000) • Transducers with 0…2500 Ω resistance output • Transducers with –1 V…+1 V or –10 V…+10 V voltage output
2 PULS INPUTS • Frequency measurement in range 0,01 Hz … 10 kHz
• Counting pulses • Tracking and recording of binary signal (shorting or disconnecting) |
Display |
Yes |
Display technology |
LCD color |
Touchscreen |
Yes |
Display languages |
Italian, English, Pol |
Display dimensions |
4 " |
Voltage type |
24 Vdc |
Recovery battery |
Not available |
Type of electrical connection |
Screw terminals |
Reverse polarity protection |
No |
Status LED |
Power supply LED |
Datalogger |
Yes |
Memory |
2GB |
Export formats |
.txt |
Storable interval |
Adjustable from 2s to 24h |
Absorbed power |
6 W |
Operating voltage |
20...30 Vdc |
Datalogger features |
• Recording data to internal 2GB memory, local access to recorded data through USB port on the front panel • Data recording rate between 2 s and 24 h; two recording frequencies toggled upon exceeding the set alarm thresholds
|
Keypad details |
No keypad |
Hole/template dimensions |
138+1 mm X 68+0.7 mm (Maximum panel thickness: 5 mm) |
Accuracy |
For RTD input ± 0.5 °C (typically ± 0.3 °C)
For 4...20mA input ±0.1% of the range (typically ±0.05% of the range)
For pulse input 0.02% |
Standards and Certifications |
RoHS, Directive 2014/35/EU “Low voltage Directive”, Directive 2014/30/EU “Electromagnetic compatibility Directive” |
EMC applied harmonized standards |
EN 61326 (For industrial applications) |
CE omologation |
Yes |
Low voltage applied harmonized standards |
EN 61010-1: 2010 |
Rohs applied harmonized standards |
EN IEC 63000:2018 |
Type of packaging |
Carton BOX |
Contains batteries |
No |
ETCN |
N/D |
country of origin |
Poland |
Customs Code |
90268020 |
Gross weight |
1,5 kg |
Net weight |
1 kg |
Packaging volume |
0,009 m³ |
Packing length |
40 cm |
Packaging width |
27 cm |
Packaging depth |
16 cm |