Principle of measurement |
Turbine |
Informations measured |
Volumetric flow, Volume |
Detection type |
Continuous measurement |
Measurable media |
Beer, Coffee, Water., Water, distilled, Food Liquids, Aggressive Liquids, Alkalis liquids, Acid liquids, Basic liquids, Demi water, (the indications on liquids are indicative and vary with the configuration of the product) |
Documentation included |
English instructions manual |
Explosion protection |
Safe zone |
Minimum process fluid temperature |
-10 °C |
Maximum process fluid temperature |
65 °C |
Maximum process pressure |
20 Bar |
Measurement type |
With contact |
Ambient temperature |
-10...+65°C |
Sensor type |
Hall-effect sensor |
Flow max (liquid) |
0,56 L/min |
Flow min (liquid) |
0,041 L/min |
Properties of the fluid |
Non-conductive (µS / cm <20) |
Installation position |
Horizontal |
Flow direction |
Unidirectional |
All signal outputs available |
NPN Pulses, PNP pulses |
Signal Output Type |
Pulse/frequency |
Details of the signal outputs |
Square wave NPN type signal with 50% duty cycle |
Pulse factor |
2063 imp/L |
Output details |
1 x NPN Open collector |
Digital output functions |
Volume |
Digital output type |
NPN |
Number of digital outputs |
1 |
Switchable current |
20 mA |
Voltage type |
24 Vdc |
Type of electrical connection |
3Pin- AMP 2.8 x 0.8 mm |
Reverse polarity protection |
No |
Max current consumption |
0,008 A |
Operating voltage |
3,8...24 Vdc |
Process connection type |
Threaded GAS(M) |
Diameter process connection |
1/4" - DN6 |
Nominal pressure (PN) |
PN20 |
Materials in contact with the measured fluid |
AISI 303 (1,4305) - Stainless steel, PBT - polybutylene terephthalate, PPS (RYTON®) - Polyphenylene sulfide, PVDF (KYNAR®) - Polyvinylidene fluoride, MVQ - Silicone |
Seal materials |
MVQ - Silicone |
Body material |
PBT - polybutylene terephthalate |
Height |
67 mm |
Width |
77 mm |
Depth |
43 mm |
Impeller material |
PVDF (KYNAR®) - Polyvinylidene fluoride |
Bearings materials |
None |
Axle/shaft materials |
AISI 303 (1,4305) - Stainless steel |
Diameter of the nozzle |
1 mm |
Additional nozzle |
Yes |
Number of items |
2 Magnets |
rotation speed |
<500 rpm |
Materials of the magnets |
CERAMIC - Ceramics, Fe - Iron, O - Oxygen, Sr - Strontium |
Accuracy |
±2,0% Full scale |
Repeatability |
±0,25% Full scale |
Maximum pressure drop |
1 Bar |
Naval approvals |
None |
Atex approvals |
None |
Standards and Certifications |
RoHS, Directive 2014/35/EU “Low voltage Directive”, IEC 61000-6-3:2006 (second edition), IEC 61000-6-1:2005 (second edition) |
EMC applied harmonized standards |
EN 55014-1:2000/A1:2011/A2:2002, EN 61000-6-3:2001/A11:2004, EN 61000-3-2:2006, EN 61000-3-3:1995/A1:2001/A2:2005, EN 55014-2:1997/A1:2001 |
CE omologation |
Yes |
Low voltage applied harmonized standards |
EN 61010-1: 2010 |
Rohs applied harmonized standards |
EN IEC 63000:2018 |
Type of packaging |
Carton BOX |
Contains batteries |
No |
country of origin |
Switzerland |
Customs Code |
90261021 |
Gross weight |
0,2 kg |
Net weight |
0,1 kg |
Packaging volume |
0,001 m³ |
Packing length |
11 cm |
Packaging width |
12 cm |
Packaging depth |
5 cm |