FCH-m-PP-Chemie Turbine flow meter - 96103036

FCH-m-PP-Chemie Turbine flow meter for aggressive liquids
Technical specifications based on the configuration
Measuring range 0,03...3,0 l/min
Process temperature -20...+90°C
Signal output PNP - 3400 p/lt
Process pressure -0,7...4 bar

Thanks to the PP body, the PVDF impeller and the EPDM seals, the FCH sensor can be used in the monitoring of chemically aggressive flows.

The sensor works up to 90 °C and withstands a maximum pressure of 4 bar. The inner diameter of 1.6 mm inside allows to work with flow rates up to 3.0 lt/min with a wide rangeability from 1: 100.

The turbine has a good repeatability of ±0.5% and an accuracy of ±2% which can be improved by performing a calibration in the field by modifying the calibration factor.

The sensor is powered at 24Vdc and the output signal is PNP type which allows a direct connection with a PLC.

For use, a close-mesh filter of about 200 mesh is recommended to avoid compromising the internal helix and it is essential to maintain straight sections before and after the installation of the sensor to ensure its accuracy and repeatability.

ORDER CODE:
96103036

Price per Unit

€72.00(Vat excluded)
€87.84(Vat included)
Qty Unit price
(Vat excluded)
Unit price
(Vat included)
1 €72.00 €87.84
Availability
25 working days
Quantity
Measurement techniques
Come Funziona un Sensore ad Ultrasuoni: Utilizzo e Funzione

Come Funziona un Sensore ad Ultrasuoni: Utilizzo e Funzione

Come Funziona un Sensore ad Ultrasuoni: Utilizzo e Funzione

Read more
press_rel_ass_riels

Pressione Relativa e Assoluta: le differenze e come misurarla

Pressione Relativa e Assoluta: le differenze e come misurarla

Read more
Confronto tra flussimetri analogici e misuratori di portata digitali

Confronto tra flussimetri analogici e misuratori di portata digitali

Confronto tra flussimetri analogici e misuratori di portata digitali

Read more
pressostato_riels

Manuale per l’uso corretto del Pressostato

Manuale per l’uso corretto del Pressostato

Read more