Loading...

FCH Flowmeter turbine powered.

FCH Flowmeter turbine powered. For non-viscous liquids. Flow rates up to 10 l/min

FCH Flowmeter turbine powered. For non-viscous liquids. Flow rates up to 10 l/min
Measuring principle turbine powered
Measuring range up to 10 l/min
Output signal of Hall effect, square wave PNP
Process connection  2x1/4" BSP 
Material body in POM. rotors PVDF, seals FKM
Temperature up to 80°C - Pressure max 10 bar
Price from € 85,00

The turbine flow sensor is used in many sectors: beverage, chemical and semi-conductors.


It has an output PNP to be interfaced to an external display, a PLC or a system of supervision. 

This turbine flow sensor finds its application in liquids as water, diesel, oil and non-aggressive liquids.

Technical Characteristics

Measuring principle:
    • Turbine
    Measuring range / adjustment:
      • 0.1÷10 [l/min]
      Precision Class:
        • ±2% VFS
        Outputs available:
          • PNP
          Operating voltage [V]:
            • 5÷24 Vdc
            Operating temperature:
              • -20÷+80 [°C]
              Pressure max:
                • 6 [Bar]
                Process connection:
                  • Threaded: G 1/4"
                  Materials in contact with the media:
                    • FKM
                    • POM
                    • PVDF
                    • [Depending on the model]
                    Approvals:
                      • EC Declaration of Conformity