Loading...

M9 Insertion turbine flow meter with Flow monitor.

M9 Insertion turbine flow meter with large graphic display of 4

M9 Insertion turbine flow meter with large graphic display of 4
M9 insertion turbine flow meter with large graphic display of 4
Measuring principle turbine
Measuring range 1,6 a 760000 lt/min as a function of the diameter
Output signal Current - Open Collector - Relé
Process connection fittings PVC - PP - PE - Stainless steel AISI 316
Materials PC - Neoprene - EPDM 
Temperature max 70°C - Pressure max 10 bar
Price from € 640,00
Variable depending on the configuration

The new M9.02 is a powerful flow monitor designed to convert the frequency signal of flow sensors into a flow rate. M9.02 is equipped with a wide full graphic display 4” which shows measured values clearly and a lot of other useful information. Moreover, due to a multicolor display plus a powerful backlight, measurement status can be determined easily from afar also. A tutorial software guarantees a mistake-proof and fast set up of every parameters. Calibration can be performed just fixing installation features or using a reference value through a new “in-line calibration”. A 4-20mA output is available to remote flow rate to a external device. A proper combination of digital outputs allows customized setups for any process to be controlled.

Applications:
• Water treatment systems
• Industrial waste water treatment and recovery
• Water distribution
• Filtration systems
• Swimming pools & SPA
• Irrigation & Fertigation
• Leak detection
• Cooling water monitoring
• Processing and manufacturing industry
• Chemical production

Main features:
• Wide full graphic display
• Multicolor backlight
• Help on board
• Installation flexibility
• Fast, intuitive and mistake-proof calibration software
• Mechanical relay for external device control
• Solid State Relays for programmable alarms
• Multilanguage menu

Technical Characteristics

Measuring principle:
    • Turbine
    Measuring range / adjustment:
      • 1,6÷760000 [l/min] depending on the diameter
      Precision Class:
        • ±0,5% VFS
        Outputs available:
          • Open collector: MAX alarm, pulses, frequency, off
          • 4÷20 [mA]
          • SPDT contact
          • [up to the model]
          Operating voltage [V]:
            • 12÷24 [V]
            Operating temperature:
              • -20÷+70 [°C]
              Process connection:
                • Fittings
                Materials in contact with the media:
                  • FPM
                  • Stainless steel AISI 316
                  • EPDM
                  • Brass
                  • NBR
                  • PVDF
                  • [Depending on the model]
                  Degree of protection:
                    • IP65
                    Approvals:
                      • GOST R approval
                      • RoHS certificate